Ultrasound-Based Bladder Volume Assessment in Gynecological Radiotherapy: Agreement with CT/CBCT and Longitudinal Variation

Authors
  • Sara Wahab Tawfeeq

    Department of Radiation Oncology, Awat Radiation Oncology Center, Erbil, Iraq
  • Jangi Shawkat Muhialdin

    Hawler Medical University, Erbil, KRG, Iraq
  • Idress Jarjess Ahmad

    Department of Radiology, Erbil, Iraq
Abstract

Background: Consistent bladder filling is important in postoperative pelvic radiotherapy because changes in volume can alter the relationship between pelvic targets and adjacent organs at risk. CBCT provides three-dimensional verification but adds treatment-room time and imaging dose. Ultrasound offers a rapid, portable, non-ionizing method for checking bladder volume before treatment-room imaging.

Objective: To evaluate agreement between investigator-performed ultrasound (US) and reference planning CT/cone-beam CT (CBCT) bladder-volume measurements in postoperative gynecological radiotherapy, and to characterize longitudinal bladder-volume change during treatment.

Methods: This prospective, single-institution method-comparison study included 29 postoperative patients receiving adjuvant pelvic radiotherapy (14 with cervical and 15 with endometrial cancer). A total of 406 paired US-reference measurements were obtained at 14 scheduled time points from simulation to treatment day 25. Patients followed a standardized protocol of bladder emptying followed by 500 mL of water 40 minutes before imaging. US was performed with a GE LOGIQ F8 Expert system and curvilinear/convex transducer; the automated volume function used three orthogonal bladder dimensions. Three consecutive scans were obtained and the median was analyzed. Planning CT was the baseline reference and CBCT was the treatment reference. Agreement was assessed using a two-way mixed-effects, absolute-agreement, single-measure ICC and Bland-Altman methods adapted for repeated observations within patients, with patient-level bootstrap confidence intervals. Longitudinal change was evaluated with a linear mixed model.

Results: Mean bladder volume was 195.5 ± 71.6 mL by US and 199.2 ± 71.6 mL by reference CT/CBCT. The overall correlation was strong (r = 0.951, p < 0.001), and the single-measure absolute-agreement ICC was 0.950 (95% CI, 0.927-0.965). Repeated-measures Bland-Altman analysis showed a mean bias of -3.69 mL (95% CI, -6.48 to -1.27 mL), with limits of agreement of -47.52 mL (95% CI, -54.29 to -41.03) and 40.14 mL (95% CI, 36.47 to 44.26). Baseline US-planning CT bias was -2.28 mL, while treatment US-CBCT bias was -3.80 mL. In exploratory agreement-threshold analyses, 364/406 pairs (89.7%) were within 20%, 396/406 (97.5%) within 30%, 400/406 (98.5%) within 50 mL, and 405/406 (99.8%) within 100 mL. Mean reference volume declined from 249.6 ± 86.6 mL at baseline to 164.4 ± 49.3 mL on day 25; the mean participant-level percentage decline was 28.0% ± 25.5%.

Conclusion: Investigator-performed US showed close average agreement with planning CT/CBCT for bladder-volume estimation, but individual differences approaching approximately 50 mL remained within the repeated-measures limits of agreement. US may therefore be useful as a rapid preparation-screening adjunct, but it cannot verify postoperative target position or the full pelvic anatomy and should not replace clinically indicated image guidance. Patient-specific or plan-specific implementation thresholds require prospective validation against anatomy, dosimetry, workflow outcomes, and clinical endpoints.

Downloads
Download data is not yet available.
References

[1] Mundt AJ, Lujan AE, Rotmensch J, Waggoner SE, Yamada SD, Fleming G, et al. Intensity-modulated whole pelvic radiotherapy in women with gynecologic malignancies. Int J Radiat Oncol Biol Phys 2002; 52(5): 1330-1337.

[2] Chen VE, Gillespie EF, Manger RP, et al. The impact of daily bladder filling on small bowel dose for intensity modulated radiation therapy for cervical cancer. Med Dosim 2019; 44(2): 102-106.

[3] Boda-Heggemann J, Lohr F, Wenz F, Flentje M, Guckenberger M. kV cone-beam CT-based IGRT: a clinical review. Strahlenther Onkol 2011; 187(5): 284-291.

[4] Borm KJ, Junker Y, Düsberg M, Devečka M, Münch S, Dapper H, et al. Impact of CBCT frequency on target coverage and dose to the organs at risk in adjuvant breast cancer radiotherapy. Sci Rep 2021; 11(1): 17378.

[5] Tai A, Christian D, Lee R, Wu S, Li X. Relationship of PTV margin with frequency of image guided positioning. Int J Radiat Oncol Biol Phys 2012; 84(3 Suppl): S782.

[6] The Royal College of Radiologists. On Target 2: Updated Guidance for Image-Guided Radiotherapy. London: The Royal College of Radiologists; 2021. Accessed August 26, 2026. Available from: RCR On Target 2

[7] Jhingran A, Salehpour M, Sam M, Levy L, Eifel PJ. Vaginal motion and bladder and rectal volumes during pelvic intensity-modulated radiation therapy after hysterectomy. Int J Radiat Oncol Biol Phys 2012; 82(1): 256-262.

[8] Okamoto H, Murakami N, Carvajal CC, Miura Y, Wakita A, Nakamura S, et al. Positional uncertainty of vaginal cuff and feasibility of implementing portable bladder scanner in postoperative cervical cancer patients. Phys Med 2018; 45: 1-5.

[9] Ahmad R, Hoogeman MS, Quint S, Mens JW, de Pree I, Heijmen BJM. Inter-fraction bladder filling variations and time trends for cervical cancer patients assessed with a portable 3-dimensional ultrasound bladder scanner. Radiother Oncol 2008; 89(2): 172-179.

[10] Jürgenliemk-Schulz IM, Toet-Bosma MZ, de Kort GAP, Schreuder HWR, Roesink JM, Tersteeg RJHA, et al. Internal motion of the vagina after hysterectomy for gynaecological cancer. Radiother Oncol 2011; 98(2): 244-248.

[11] Wang X, Yu M, Wang J, Zhong R, Shen Y, Zhao Y, et al. An assessment of interfractional bladder, rectum and vagina motion in postoperative cervical cancer based on daily cone-beam computed tomography. Mol Clin Oncol 2016; 4(2): 271-277.

[12] Claxton K, Appleyard R. Implementation of ultrasound bladder volume scanning for patients receiving intensity-modulated radiotherapy to the cervix or endometrium: clinical experiences from a United Kingdom radiotherapy department. J Radiother Pract 2017; 16(3): 232-244.

[13] Bai F, Hu Q, Yao X, Cheng M, Zhao L, Xu L. A prospective comparative study on bladder volume measurement with portable ultrasound scanner and CT simulator in pelvic tumor radiotherapy. Phys Eng Sci Med 2024; 47(1): 87-97.

[14] Wu Y, Xue X, Su L, Liu Y. Effect of bladder volume on dose of exposure to dangerous organs and incidence of cystitis and enteritis in patients with cervical cancer after external radiotherapy. Front Oncol 2026; 16: 1760076.

[15] Wang Y, Wang M, Zhu L. The impact of bladder volume on dosimetric outcomes in VMAT for cervical cancer patients after surgery. J Gynecol Oncol 2025; 36(4): e65.

[16] Sağınç H, Yıldırım Ö, Baltalarlı B. Acute toxicities of three-dimensional conformal radiotherapy in the treatment of gynecological cancer, and retrospective dosimetric comparison of three-dimensional conformal radiotherapy and inverse intensity-modulated radiotherapy. J Surg Med 2018; 2(3): 315-319.

[17] von Elm E, Altman DG, Egger M, Pocock SJ, Gøtzsche PC, Vandenbroucke JP; STROBE Initiative. Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) statement: guidelines for reporting observational studies. BMJ 2007; 335(7624): 806-808.

[18] Kottner J, Audigé L, Brorson S, Donner A, Gajewski BJ, Hróbjartsson A, et al. Guidelines for Reporting Reliability and Agreement Studies (GRRAS) were proposed. J Clin Epidemiol 2011; 64(1): 96-106.

[19] Fedorov A, Beichel R, Kalpathy-Cramer J, Finet J, Fillion-Robin JC, Pujol S, et al. 3D Slicer as an image computing platform for the Quantitative Imaging Network. Magn Reson Imaging 2012; 30(9): 1323-1341.

[20] Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986; 1(8476): 307-310.

[21] Bland JM, Altman DG. Agreement between methods of measurement with multiple observations per individual. J Biopharm Stat 2007; 17(4): 571-582.

[22] Koo TK, Li MY. A guideline of selecting and reporting intraclass correlation coefficients for reliability research. J Chiropr Med 2016; 15(2): 155-163.

[23] Gueorguieva R, Krystal JH. Move over ANOVA: progress in analyzing repeated-measures data and its reflection in papers published in the Archives of General Psychiatry. Arch Gen Psychiatry 2004; 61(3): 310-317.

[24] Mullaney L, O'Shea E, Dunne MT, Thirion PG, Armstrong JG. A comparison of bladder volumes based on treatment planning CT and BladderScan BVI 6100 ultrasound device in a prostate radiation therapy population. Br J Radiol 2018; 91(1091): 20180160.

[25] Ung KA, White R, Mathlum M, Mak-Hau V, Lynch R. Comparison study of portable bladder scanner versus cone-beam CT scan for measuring bladder volumes in post-prostatectomy patients undergoing radiotherapy. J Med Imaging Radiat Oncol 2014; 58(3): 377-383.

[26] Haworth A, Paneghel A, Bressel M, Herschtal A, Pham D, Tai KH, et al. Prostate bed radiation therapy: the utility of ultrasound volumetric imaging of the bladder. Clin Oncol (R Coll Radiol) 2014; 26(12): 789-796.

[27] Bąk B, Kaczmarek K, Radoła D, Winiecki T, Bajon T. A prospective study of bladder volume assessment using ultrasound in prostate cancer radiotherapy: comparison with cone-beam computed tomography (CBCT). Radiography (Lond) 2025; 31(5): 103016.

[28] Wessel L, Longarino FK, Sycheva N, Bolten JH, Waldsperger H, Kozyra K, et al. Influence of interfractional variations of bladder and rectal filling on vaginal cuff movement and the role of rectal balloons in gynecological pelvic proton beam therapy. Technol Cancer Res Treat 2026; 25: 15330338261438327.

[29] Harris EER, Latifi K, Rusthoven C, Javedan K, Forster K. Assessment of organ motion in postoperative endometrial and cervical cancer patients treated with intensity-modulated radiation therapy. Int J Radiat Oncol Biol Phys 2011; 81(4): e645-e650.

[30] Rash D, Hagar Y, Cui J, Hunt JP, Valicenti R, Mayadev J. Interfraction motion of the vaginal apex during postoperative intensity modulated radiation therapy: are we missing the target? Int J Gynecol Cancer 2013; 23(2): 385-392.

Downloads
Published
06-11-2026
Section
Articles
License

Copyright (c) 2026 Sara Wahab Tawfeeq, Jangi Shawkat Muhialdin, Idress Jarjess Ahmad

Creative Commons License

This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

How to Cite

Ultrasound-Based Bladder Volume Assessment in Gynecological Radiotherapy: Agreement with CT/CBCT and Longitudinal Variation. (2026). Journal of Cancer Research Updates, 15(4), 371-381. https://doi.org/10.30683/1929-2279.2026.15.33