Evaluation of the Type and Frequency of Errors Discovered During Routine Secondary Patient Chart Review
- Authors
-
-
Michael T. Hardin
Department of Radiation Oncology, Division of Medical Physics, Sidney Kimmel Cancer Center at Thomas Jefferson University, Philadelphia, PA, USA -
Amy S. Harrison
Department of Radiation Oncology, Division of Medical Physics, Sidney Kimmel Cancer Center at Thomas Jefferson University, Philadelphia, PA, USA -
Virginia L. Lockamy
Department of Radiation Oncology, Division of Medical Physics, Sidney Kimmel Cancer Center at Thomas Jefferson University, Philadelphia, PA, USA -
Jun Li
Department of Radiation Oncology, Division of Medical Physics, Sidney Kimmel Cancer Center at Thomas Jefferson University, Philadelphia, PA, USA -
Cheng Peng
Department of Radiation Oncology, Division of Medical Physics, Sidney Kimmel Cancer Center at Thomas Jefferson University, Philadelphia, PA, USA -
Peter Potrebko
Department of Radiation Oncology, Florida Hospital Waterman Cancer Institute, Tavares, FL, USA -
Yan Yu
Department of Radiation Oncology, Division of Medical Physics, Sidney Kimmel Cancer Center at Thomas Jefferson University, Philadelphia, PA, USA -
Laura Doyle
Department of Radiation Oncology, Division of Medical Physics, Sidney Kimmel Cancer Center at Thomas Jefferson University, Philadelphia, PA, USA -
Junsheng Cao
Department of Radiation Oncology, Division of Medical Physics, Sidney Kimmel Cancer Center at Thomas Jefferson University, Philadelphia, PA, USA
-
- Keywords:
- Error analysis, chart checks, continuous quality improvement.
- Abstract
-
Purpose: Desire to improve efficiency and throughput inspired a review of the frequency and scope of our physics chart check procedures. Departmental policy mandates review of a patient’s treatment plan prior to port-filming, after first treatment and “weekly” every 3-5 fractions. This study examined the effectiveness of the “after-first” physics check with respect to improving patient safety and clinical efficiency.Methods and Materials: A shared spreadsheet was created to record errors discovered during patient-specific chart review following the first fraction of treatment and before the second fraction. First, entries were recorded and categorized from August 2014 through February 2015. Frequencies were assessed month-to-month. Next, utilizing thes e results, a continuous quality improvement (CQI) process following Deming’s Plan-Do-Study-Act (PDSA) methodology was generated. The first iteration of this PDSA was adding a dose tracking checklist item in the pre-treatment plan check assessment. A two-sided Fisher’s exact test was used to determine if there was a nonrandom association between the checklist implementation and incidence of dose tracking errors.Results: Analysis of recorded errors indicated an overall error rate of 3.4% over the 13 month period. The majority of errors related to discrepancies in documentation, followed by prescription, plan deficiency, and dose tracking-related errors. A two-sided Fisher’s exact test revealed a statistically significant decrease in dose tracking-related errors after implementing the checklist item (p = 0.0322, significance level = 0.05). Conclusions: This work indicates that this redundant secondary check is an effective QA process in our department. The first month spike in rates could be due to the Hawthorne/observer effect, but the consistent 3% error rate suggests the need for continuous quality improvement and periodical re-training on errors noted as frequent to improve awareness and quality of the initial chart review process, which may lead to improved treatment quality, patient safety and increased clinical efficiency.
- Downloads
-
Download data is not yet available.
- Downloads
- Published
- 22-01-2017
- Issue
- Vol. 6 No. 1 (2017)
- Section
- Articles
How to Cite
Similar Articles
- Priyanka Banerjee, Samir Kumar Bandyopadhyay, A Detail Process for CAD Based Breast Cancer Detection , Journal of Cancer Research Updates: Vol. 8 No. 1 (2019)
- Umesh C. Gupta, Subhas C. Gupta, Shayle S. Gupta, The Under appreciated Role of Lifestyle and Nutrition in Cancer Prevention, Genesis, and Treatment , Journal of Cancer Research Updates: Vol. 7 No. 4 (2018)
- Jui-Teng Lin, Kuo-Ti Chen, Hsia-Wei Liu, Analysis of Kinetics and Efficacy of Anti-Cancer via Oxygen-Enhanced Photodynamic Therapy , Journal of Cancer Research Updates: Vol. 7 No. 1 (2018)
- Hirendra Banerjee, Jamel Joyner, Monet Stevenson, William Kahan, Christopher Krauss, Sasha Hodges, Eduardo Santos, Myla Worthington, Jeffferey Rousch, Gloria Payne, Vinod Manglik, Narendra Banerjee, Brianna Morris, Dayton Bell, Santosh Mandal, Short Communication: Studying the Role of Smart Flare Gold Nano Particles in Studying Micro RNA and Oncogene Differential Expression in Prostate Cancer Cell Lines , Journal of Cancer Research Updates: Vol. 6 No. 2 (2017)
- Lisa Billecke, Eva Maria Murga Penas, Jozef Zustin, Thorsten Derlin, Carsten Bokemeyer, Georgia Schilling, Extramedullary Plasmacytoma of the Lung - Rather a Disseminated than a Localized Disease? - A Case Report of a Primary Pulmonary Plasmacytoma Showing Distinct Signs of Systemic Spread , Journal of Cancer Research Updates: Vol. 1 No. 1 (2012)
- Bibo Wang, Yiping Han, Jiajie Zang, Expression of p63 in Squamous Cell Carcinoma of the Lung and its Diagnostic Significance: A Meta-Analysis , Journal of Cancer Research Updates: Vol. 1 No. 2 (2012)
You may also start an advanced similarity search for this article.
Most read articles by the same author(s)
- Kaiguo Yan, Laura Doyle, Haisong Liu, Pramila Rani Anne, Amy Harrison, Yan Yu, Junsheng Cao, Template-Based Inverse PlanningSimulated Annealing for CT-Based High-Dose-Rate Brachytherapy of Cervical Cancer: Feasibility Study , Journal of Cancer Research Updates: Vol. 2 No. 1 (2013)